Common Faults of Air Compressors
1. Power loss fault: the air Compressor's power supply / control power supply loses power. Check whether the power supply and control power supply have electricity.
2. Motor temperature too high: if the motor starts too frequently, is Overloaded, is insufficiently cooled, has problems with the motor itself or bearings, sensors, etc. Limit the motor start times and reduce the loading set pressure.
3. Compressor temperature too high: the temperature of the oil-gas mixture at the air compressor outlet reaches 120 degC. You need to keep the air compressor well ventilated, check that the radiator is free of debris cover and dissipates well, check the air compressor oil level, Cooling fan, and temperature sensor.
4. Pressure too high: the compressor outlet pressure reaches 15 bar and trips. Check whether the loading set pressure is too high, the pressure sensor, etc., and contact Maintenance to check the pressure regulating valve and unloading valve.
5. Motor rotation direction error: wrong motor wiring, or the star/delta fails to switch normally at start, or a fault in the rotation signal sensor on the compressor body causes the air compressor to report a motor rotation direction error. Don't panic; contact maintenance to check whether the motor phase sequence wiring is correct.
6. Reduced exhaust volume: check the gas valve; if it leaks, either choose lapping repair or replace it with a new valve. It may also be that the piston ring, scraper ring, or cylinder is excessively worn - unavoidable, and can only be replaced promptly. If none of these are the problem, lightly check the air filter for blockage or air pipeline leakage, clean dust from the filter screen, and repair the pipeline.
7. Exhaust temperature or cooling water discharge temperature too high: this fault has five possible problems. If the cylinder is scored causing overheating, repair the cylinder and piston promptly. When the exhaust valve leaks or the valve spring or valve plate is damaged, replace the part promptly. Check whether cooling water is insufficient and adjust to increase the flow. If the cooling water path is blocked by excessive scale in the cylinder, cylinder head, and cooler, clear the scale and unblock. Also check the intake and exhaust valves; if carbon deposits form, clean them promptly.
Judging Thermostat Faults: The premise for judging a thermostat fault is normal cooling effect, while the compressor runs without stopping.
First check whether the sensing tube has come off its normal position and whether the thermostat fixing screw is loose; re-adjust and observe the cooling effect. If the refrigerator compartment has dropped below 10 degC and the freezer below 0 degC, but it still does not stop after appropriately raising the thermostat control temperature, check the thermostat again.
There is a simple way to judge whether the thermostat contacts can open: remove the thermostat and place it in the freezer compartment of a refrigerator or the upper basket of a freezer, close the refrigerator or freezer door, short-circuit the two wires connected to the thermostat, let the compressor run for about 30 minutes, then take out the thermostat and quickly use a multimeter on the R x 1 range to measure whether its two contacts can open (rotate the thermostat to the mid-cold position before placing it in the refrigerator). If it still cannot open at low temperature, the sensing agent has leaked out and it needs replacement. If the contacts can open and the sensing head has not deviated from its normal position, the system is low on refrigerant and needs recharging. At room temperature the thermostat contacts are closed, and at the set low temperature they can open. This principle can be used to judge whether the thermostat is normal and whether the system is low on refrigerant. But note that if the inner liner is frozen too thick or the placed food is too hot or too much, the compressor will also not stop. For excessively thick inner liner ice, refrigerators with a defrost circuit should first check whether the defrost circuit is normal; those without should first stop and manually defrost, then restart to clear the non-stop fault.
This concludes the knowledge about refrigerator Compressor Repair. If you are unclear, you can refer to the above article to learn. Refrigerator compressor repair is difficult; when encountering problems, it is best to find professional repair personnel to avoid damaging the compressor.